Product Information:PZ-CAP

Winding type conductive polymer aluminum electrolytic capacitors(PZ-CAP) FAQ

Q1:
What technique is used for realizing high working voltage?
A1:
We have established our original polymerization method and manufacturing process.
See Technical Notes for the detail.
Page top
Q2:
Which is the failure mode of the capacitor?
A2:
It is open mode.
However if excessive voltage, excessive ripple current or reverse voltage is applied to the capacitor, the capacitor may short-circuit. It is the same as for non-solid electrolytic capacitor.
Page top
Q3:
Is voltage derating necessary?
A3:
It is no need of voltage derating for PZ-CAP.
You can apply up to the rated voltage within the specified condition.
Page top
Q4:
How long is the life of PZ-CAP?
A4:
The life of PZ-CAP depends on operating temperature and heating with ripple current.
Some item is different from the electrolyte type of life estimation.
Please consult us for the detail.
Page top

1938-1, Nishi-Minowa Ina City, Nagano 399-4593 Japan TEL:0265-72-7111 FAX:0265-73-2914